Back to the overview

Brands we support

We read the inverter on the site, not through the manufacturer's cloud app. Those apps are useful for a first look, but they update too slowly for a loop that has to shed load in seconds.

Two readers are in the controller today. One talks to Solar Assistant over MQTT, if you already have it. The other is a direct Modbus link for single-phase Sunsynk and Deye units. Both have been tested in software. Neither has been plugged into a live inverter yet. Everything else on this page is planned.

  • Bench testing The reader is in the controller. It has not been connected to a live inverter yet.
  • Planned We intend to add a local reader. It is not in the controller yet.
  • Cloud only We can look at a portal during a survey, but miners would need a local meter or logger first.
Brand Typical models How we read it Status
Sunsynk 5 kW, 8 kW and 12 kW single-phase hybrids; 8 kW to 50 kW three-phase; high-voltage HP3 series. Direct Modbus RTU over RS485, or the logger (Solarman V5). Solar Assistant MQTT if you already run it. Three-phase units use a different register map. Bench testing single-phase
Planned three-phase
Deye SUN-xK-SG01LP1 and SG05LP1 single-phase; SG01LP3 and SG04LP3 three-phase; SG01HP3 high-voltage three-phase. Same hardware family as Sunsynk. Same paths as Sunsynk: Modbus RTU over RS485, or the logger, or Solar Assistant MQTT. We key the register map on the model family, not the badge. Bench testing single-phase
Planned three-phase
Victron MultiPlus-II and Quattro or Quattro-II 48 V inverter-chargers, read through a Cerbo GX or another Venus OS GX device. MQTT or Modbus TCP (port 502) on the GX, once those services are enabled. Solar Assistant also lists MultiPlus-II. The VRM cloud API is for a survey only. Planned
Growatt SPH hybrids; MIN-XH and MOD-XH; WIT series; some SPF off-grid units. Modbus RTU or Modbus TCP. Solar Assistant covers many of these models. ShinePhone or ShineServer is cloud only. Planned
GoodWe ET, EH and ES hybrids, including the common GW5K-ET to GW10K-ET class and three-phase ET units. Local LAN through the dongle (UDP 8899 or Modbus TCP). Solar Assistant covers a range of GoodWe models. Older dongle firmware can block local access. SEMS is cloud only. Planned
SolarEdge HD-Wave and Energy Hub or StorEdge systems, typically in the SE5K to SE10K class, plus three-phase units. Local Modbus TCP if the installer has enabled it (often port 1502). The official monitoring API updates too slowly for the control loop. Solar Assistant does not list most SolarEdge models. Planned local Modbus TCP
Cloud only otherwise
Huawei SUN2000 KTL-L1 single-phase; KTL-M1, M2 and M3 three-phase, often with LUNA2000 storage. Modbus TCP through the Smart Dongle (port 502) or the inverter on the local network. Solar Assistant lists several SUN2000 families. FusionSolar is cloud only. Planned
SMA Sunny Boy and Sunny Tripower; Sunny Boy Smart Energy or Sunny Island where a battery is fitted. Official Modbus TCP on port 502, disabled by default and turned on in the inverter or System Manager interface. Solar Assistant does not list SMA. Sunny Portal is cloud only. Planned
Kodak, Must and Axpert-type Kodak OG, King and Max ranges; Must PH and PV series; Voltronic Axpert MKS, MAX and similar rebrands. Maps vary by the exact unit. RS485, USB or RS232, depending on the board. Solar Assistant lists Kodak, Must and Voltronic when the unit is that family. We would confirm the map on site rather than assume a Sunsynk-style layout. Planned
RCT Axpert Axpert King, MKS, VM, MK4 and MAX ranges, including MK4 Twin and AXMX2. Voltronic-style serial protocol over RS232 or USB. Solar Assistant lists RCT Axpert models and connects them as Voltronic, if you already run it. Some newer units also list RS485; on the manuals we checked that port is for the battery BMS, not a documented inverter Modbus map. Planned
Solis S5 and S6 hybrids (EH1P single-phase, EH3P three-phase); older RHI hybrids. Local Modbus. Solar Assistant lists several S5, S6 and RHI hybrids. Planned
Sigenergy SigenStor EC and Sigen Hybrid, single-phase and three-phase. Official Modbus TCP (port 502, enabled in the app) or RS485. Plant-level reads use unit ID 247. Solar Assistant lists SigenStor EC. Planned
Fronius Primo and Symo string inverters; GEN24 Plus hybrids. More common on commercial and larger grid-tied roofs. Official Modbus TCP or RTU (SunSpec) and the local Solar API. Solar Assistant does not list Fronius. Solar.web is cloud only. Planned
Luxpower SNA single-phase hybrids; LXP-LB hybrids and AC-coupled LXP units. RS485 Modbus. The port often accepts only one client, so the Wi-Fi dongle may need to come off. Solar Assistant documents the SNA and LXP families. Planned
Sungrow SH hybrids (including SH-T and SH-RT) and SG string inverters, often on larger commercial roofs. Local Modbus or the WiNet logger. Solar Assistant lists some SH and SG models. iSolarCloud is cloud only. Planned
ATESS Commercial hybrid and storage systems, less often on suburban roofs. A reliable local protocol has not been confirmed for our controller. Solar Assistant does not list ATESS. Cloud only

If you already run Solar Assistant on a listed brand, that is the path we would try first, through the MQTT reader already in the controller. Manufacturer clouds (Sunsynk Connect, Solarman, VRM, SEMS, FusionSolar, Sunny Portal, Solar.web and the rest) stay out of the control loop.

Not listed? Send us a photo of the inverter label.

Use the site form and mention the brand if you know it. A photo of the rating label is the quickest way to identify a rebranded or unusual unit. We will ask for that when we reply.

Check your site